Test Code LAB346 FACTOR V LEIDEN
Acceptable Collection Tube(s) or Specimen
Lavender
Specimen Draw Volume
Volume: 4.0 mL
Minimum Volume: 2.0 mL
Processing Instructions
Draw 4 mL in an EDTA Lavender Top tube. Minimum volume is 0.5 mLs Send separate lavender top tube for this test unopened to laboratory refrigerated.
Performed Test Frequency
Tuesday
Methodology
PCR
CPT(s)
81241
Performing Location
MercyOne Des Moines Laboratory, Molecular