Test Code GAG Giardia Antigen
Cerner Test Code
Giar Ag
Acceptable Collection Tube(s) or Specimen
Orange Cap Cary-Blair
Processing Instructions
Transfer specimen to an Orange Cap Cary-Blair container within 2 hours of collection. Using the collection spoon attached to the cap, add specimen until the liquid reaches the red line. Do not overfill container past the red line.
Stability
Stability: Preserved specimen is stable for 2 weeks refrigerated. Specimens, although stable for 2 weeks, are only kept in the lab 1 week.
Performed Test Frequency
Everyday
CPT(s)
87269
Performing Location
Test performed at MercyOne Clinical Lab, Des Moines, IA, Microbiology.
Rejection Criteria
Swabs are not acceptable.