Sign in →

Test Code FHGB Plasma Free Hemoglobin

Cerner Test Code

FREEHGB

Acceptable Collection Tube(s) or Specimen

Preferred: Li Hep GRNL

Acceptable: Lavender

Specimen Draw Volume

Volume: 2.0 mL

Minimum Volume: 1.0 mL

Processing Instructions

Collect a fresh sample without using a tourniquet to avoid hemolysis. Do not use plasma separator devices. Lithium heparin anticoagulant is preferred but edta is also acceptable. Transport promptly to the laboratory. Plasma needs to be removed from cells within 2 hours of collection. If testing is to be delayed, remove plasma from cells using caution to avoid in-vitro hemolysis or contamination. Frz aliquot.

Stability

Stability: Several months Frozen at -20

Performed Test Frequency

Everyday

CPT(s)

83051

Performing Location

MercyOne Des Moines Laboratory, Chemistry

Rejection Criteria

Rejection criteria: Hemolysis and Gel tubes