Test Code DRVVT Dilute Russells Viper Venom Test

Cerner Test Code

DRVVT

Acceptable Collection Tube(s) or Specimen

Blue

Specimen Draw Volume

Volume: 5.4 mL

Minimum Volume: 5.4 mL

Processing Instructions

Draw 5.4 ml -put in 2 Blue Top tubes. Tube must be filled appropriately to the fill line to ensure accurate results. Centrifuge and remove plasma, centrifuge plasma again and place 2 ml of platelet-poor plasma in an aliquot tube and freeze

Stability

Stability: Plasma Room Temp 4 hrs , Frozen 1 month

Performed Test Frequency

Monday|Wednesday|Friday

CPT(s)

85613

Methodology

Electromechanical

Performing Location

MercyOne Des Moines Laboratory, Hematology

Rejection Criteria

Rejection criteria: Refrigerated plasma.